Shelby S.

Shelby S. Job Checkin

CLEAN HORIZONTAL COIL & PAN IN A/H LVL1 NO REMOVAL W/ LIGHT SELF RINSING CHEMICAL TO PREVENT POSSIBLE MOLD FROM BEING DISPERSED IN YOUR HOME, YOU MUST KEEP YOUR EVAPORATOR COIL CLEAN. IF NOT CLEANED, DUST AND DEBRIS CAN CAUSE MOLD OR MUSTY ODORS. DUE TO STUBBORN DEBRIS, SPECIAL CHEMICALS WILL BE USED TO CLEAN THE COIL.


Shelby S.

Shelby S. Job Checkin

I performed a singlee system cooling maintenance. I checked amps, capacitor, filter, electrical, drains, cleanliness, and refrigerant. I found that the primary drain was clogged in the p trap. I performed a drain clear with drain treatment and ensured that it was clear and free flowing. I found that the system was low on refrigerant charge. I did not notice any leak during service so I charge it with 4 pounds are 410a. The original delta was 10 degrees. The new delta is 19 degrees. The system is supplying 55 degree air. I collected for the drain clear and refrigerant. I will need to return with no rinse coil cleaner on Tuesday the 6th between 10-12.